Skip to Main Content
Mueller MAXXimizer L-40 Package Chiller
Mueller MAXXimixzer Chiller
Mueller MAXXimizer L-40 Package Chiller
Mueller MAXXimixzer Chiller

MAXXimizer Package Chiller

    • Dairy Farm
    • Refrigeration & Chilling
    • Cooling & Chilling
  1. Features

    • Plug-and-play design makes installation easy and requires minimal plumbing and wiring
    • Sized for a wide range of operating conditions from 0 to 110 degrees Fahrenheit
    • Measurements (L x W x H)
      • 13'10" x 3'0" x 7'4"
      • 4.22m x .91m x 2.24m
    • Built with existing components, servicing your equipment is simple and straightforward.
    • Hefty 140-gallon (529.96-liter) propylene glycol reservoir
    • Automatic compressor rolling starts
    • E-Star® HiPerForm® electronic valve control delivers precise and instantaneous refrigerant control
    • System advanced alerts and alert history via MilkSecure™ technology
    • Compatible with R448a and R507 refrigerants
    • Indoor or outdoor installation options
    • Automatic redundant pump control
    • Remote start capability  
  2. Specifications

    R-507 Refrigerant
    Horsepower (kW)Number of Refrigeration CircuitsVoltageGlycol Connections - in (cm)Flow Range - gpm (lpm)Head Range - ft (m)Btu/hr1Approx. Shipping Weight Crated - lbs (kg)
    40 (29.4) 4 230/60/3 3 (7.6) 100 - 300 (378.5 - 1135.6) 35 - 65 (10.7 - 19.8) 340,800 4,800 (2177.2)
    40 (29.4) 4 460/60/3 3 (7.6) 100 - 300 (378.5 - 1135.6) 35 - 65 (10.7 - 19.8) 340,800 4,800 (2177.2)
    R-448A Refrigerant
    Horsepower (kW)Number of Refrigeration CircuitsVoltageGlycol Connections - in (cm)Flow Range - gpm (lpm)Head Range - ft (m)Btu/hr1Approx. Shipping Weight Crated - lbs (kg)
    40 (29.4) 4 230/60/3 3 (7.6) 100 - 300 (378.5 - 1135.6) 35 - 65 (10.7 - 19.8) 288,000 4,800 (2177.2)
    40 (29.4) 4 460/60/3 3 (7.6) 100 - 300 (378.5 - 1135.6) 35 - 65 (10.7 - 19.8) 288,000 4,800 (2177.2)
    40 (29.4) 4 575/60/32 3 (7.6) 100 - 300 (378.5 - 1135.6) 35 - 65 (10.7 - 19.8) 288,000 4,800 (2177.2)

    All MAXXimizer chillers are equipped with two 5-horsepower (3.7 kW) water circulation pumps. 

    Based on compressor manufacturer’s data at 20°F (-6.7°C) SST and 100°F (37.8°C) CT. Actual Btu/hr output and energy usage may vary depending on field conditions. 230 V/ 60 Hz fan motor circuit.