Self-Contained Air-Cooled Refrigeration Unit

Paul Mueller Company's large horsepower self-contained, air-cooled refrigeration units arrive at the dairy ready to make money. Save days of soldering accumulators, receivers, and remote condensers. These self-contained units coupled with Mueller Fre-Heaters® and an LS series chiller are a cooling force to be reckoned with. Driving this packaged chiller system is the Mueller Multi-Stage chiller control. Set the unit to cycle on and off based off your milk flow. Real-time milk temperatures sensed by the Mutli-Stage chiller control engage only the units necessary to perform your cooling at that specific moment.

Features

  • Liquid receiver with relief valve.
  • Inlet and outlet service valves.
  • High-pressure safety valve.
  • Low-pressure operating control.
  • Crankcase heater.
  • Compressor contactor.
  • Separate subcooling circuit.
  • Head pressure valves.
  • Single unloader on 15- to 40-hp models.
  • Main power disconnect.
  • Control circuit transformer (460-volt units).
  • Direct-drive condenser fans.
  • Fan motor thermal protection.
  • Pressure fan cycle control.
  • Removable access panels.
  • Weatherproof electrical panel.
  • Hinged control panel access.
  • Vibration isolation under compressor.
  • Suction and discharge vibrasorber.
  • Electronic oil pressure control.
  • Service run/pump-down switch.
  • Accumulator heat exchanger (factory installed).
  • Fan motor contactor.
  • A low ambient heated receiver kit for use when units are subject to normal ambient temperatures 30°F or below is available as an option.

Specifications and Sizing

Air-cooled Unit Specifications
Model No. Compressor Qty HP Condenser Fan Motor Connections Receiver CapacityR-507 (lb)
208-230/3
RLA/LRA
460/3
RLA/LRA
208/3 230/3 460/3 Suction (in) Liquid (in)
DS15H2 59.6/275 29.0/138 2 1.5 9.6 9.2 4.6 1.625 0.875 123
DS20H2 66.0/308 33.0/154 2 1.5 9.6 9.2 4.6 1.625 0.875 123
DS25H2 82.2/428 41.1/214 3 1.5 14.4 13.8 6.9 2.125 1.125 188
DS30H2 94.0/470 47.0/235 3 1.5 14.4 13.8 6.9 2.125 1.125 188
DS35H2 107.0/565 53.5/283 4 1.5 19.2 18.4 9.2 2.125 1.125 188
DS40H2 142.0/594 71.0/297 4 1.5 19.2 18.4 9.2 2.125 1.125 188

Note: Chiller capacities at 20°F evaporator, 95°F ambient. Receiver capacity at 90% full.